8
Projects for HVAC work * Chilled Water Systems (Air Cooled / Water Cooled) * Chilled Beans / District Cooling * Smoke Ventilation and Management * Boilers (Steam and Water) * Floor Heating * Variable Air Volume * Venturi Type Variable Air-Flow Controllers * Ducting and Insulation * Grilles and Dampers * Energy Recovery * BMS and Controls
G S Air Cool offers the maintenance of different types of air conditioners. 20 Technical service teams consisting of a technician and helper on a two wheeler with a mobile. Total service strength as on date is 80. 1 office service support staff to coordinate between customers & their complaints with the field staff. Customer support software designed by Care Software for imparting efficient & quick after sale service.
VRF System Variable Refrigerant Flow VRF zoning is an energy-efficient method of providing precise comfort control to indoor environments. VRF offers a wide variety of applications - everything from spot-cooling or -heating a single room in a home (using a split-ductless system) to a large commercial building with multiple floors and areas (that require individual comfort control delivered by a split-zoning system.
All Type Air-conditioner Maintenance Services Under AMC & CMC Contract Why maintenance is required? The principle of preserving the equipment for preventing any malfunction either before they occur or before they develop into major defects is Maintenance. The prime end of safeguarding is to eliminate the consequences of malfunction of equipment.  Our maintenance program shall help you to prevent all equipment failure before if occurs. All air conditioner  systems, like any other machine depreciate with time and if not maintained, they lose efficiency, consume more power & reduce your profits. The good news, however, is that you can recover most of that lost efficiency through regular maintenance.
Cooling Tower The cooling tower is a device where heat rejection takes place. At the tower, waste heat is extracted to the atmosphere by having the water stream cooled to a reduced temperature. The heat rejection type at the cooling tower is referred to as ‘evaporative’ where a small water portion is allowed to evaporate into the moving air and provides a significant cooling effect on the rest of the water stream. The common applications where the cooling tower is used are such as providing cool water needed for air conditioning, refrigeration and other industrial uses.
Environment Friendly Refrigerant R22 To R410 There are two types of refrigerants used by air conditioning units and these are R22 and R410A. The continued use of these refrigerants is largely explained by the fact that they are environment friendly refrigerants and not likely to pose serious environmental risks like their other counterparts. The R22 refrigerant is generally an HCFC or single hydro chlorofluorocarbon compound. Besides its potential of causing ozone depletion being low, this refrigerant also has a low content of chlorine, which makes it a friendly compound to the environment. It was rumored that manufacturing of R22 would be stopped from the year 2010 and only recycled can be used. The R410 refrigerant is non- CFM which makes it environmentally friendlier compared to most of the other refrigerants. The best thing with using R410 is that even if it leaks and escapes your refrigerant, it doesn’t contribute to the depletion of the ozone layer. Ideally, R410 was manufactured to replace R22, which proved to be a threat to the environment and due to serious international concerns on the environment; R22 is expected to be phased out completely by 2020. Scientists discovered that R22, which was the most commonly used refrigerant in air conditioners, contributed greatly to the depletion of the ozone layer. R410 was passed for use during Montreal Protocol treaty as it was found not to contribute to depletion of the ozone layer. Unlike the alkyl halide refrigerants which largely comprise of chlorine and bromine, R410 only contains fluorine and doesn’t cause ozone layer depletion. For this reason, it is becoming used more widely by manufacturers who are keen to phase out refrigerants that deplete the ozone layer and contribute greatly to environmental pollution such as R-22. Despite this, R410 also has some issues as its global warming potential is considerably high.
window air conditionerwindow acwindow coolerac gas fillingtypes of refrigerant